Skip to main content
Skip table of contents

Observation-BNet-Child-BirthType

FHIR Resource information

FHIR Resource

🌍Observation-BNet-Child-BirthType. Based on 🌍 Observation

Description

Type of birth.

Release status

LIVE

Cardinality

Single

Writing to Spine permitted

NO

Spine filters

None

FHIR Observation resource details

Observation details

Code

118215003 (🌍 snomed)

Value type

🌍CodeableConcept

Resource Element

valueCodeableConcept

Mandatory

Yes

Uses effectiveDateTime

No

Data Dictionary item

BirthType - Type of birth
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - DataSet: (PREGSUMUK) UK PREGSUM Maternity Data set
   - Topic: (LabourBirth) Labour and birth

Key FHIR Resource elements used

* id - Unique resource identifier

Summary

Unique resource identifier

Mandatory

Yes

Expected type

🌍string

Write allowed

No

Data Dictionary item

None

* status - Fixed code for the status of this observation

Summary

Fixed code for the status of this observation

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'final' should be used.

valueCodeableConcept - Type of delivery

Summary

Type of delivery

Mandatory

No

Expected type

🌍CodableConcept

Write allowed

Yes

Data Dictionary item

None

Value set used

🌍ValueSet-BNet-Preg-BirthType

subject - This element provides the reference to the pregnant person/mother

Summary

This element provides the reference to the pregnant person/mother

Mandatory

No

Value type

🌍Reference(Patient)

Write allowed

Yes

Data Dictionary item

None

focus - Reference to the child patient resource

Summary

Reference to the child patient resource

Mandatory

No

Value type

🌍Reference(Patient)

Write allowed

Yes

Data Dictionary item

None

encounter - Reference to the labour and birth encounter

Summary

Reference to the labour and birth encounter

Mandatory

No

Value type

🌍Reference(Encounter)

Write allowed

Yes

Data Dictionary item

None

Example JSON when READING from the Spine

JSON
{
  "resourceType": "Observation",
  "id": "4F62736572766174696F6E2D424E65742D4368696C642D426972746854797065",
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "118215003"
      }
    ]
  }
}


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.