Skip to main content
Skip table of contents

Procedure-BNet-Preg-UltrasoundScan

FHIR Resource information

FHIR Resource

🌍Procedure-BNet-Preg-UltrasoundScan. Based on 🌍 Procedure

Description

Ultrasound scans

Release status

IN TEST

Cardinality

Single instance

Writing to Spine permitted

NO

Spine filters

None

Key FHIR Resource elements used

* id - Unique resource identifier

Summary

Unique resource identifier

Mandatory

Yes

Expected type

🌍string

Write allowed

No

Data Dictionary item

None

* Status - Status of the observation

Summary

Status of the observation

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'completed' should be used.

* subject - Reference to the mother/pregnant person

Summary

Reference to the mother/pregnant person

Mandatory

Yes

Value type

🌍Reference(Patient)

Write allowed

Yes

Data Dictionary item

None

* extension:recorded - When the procedure was first captured in the subject's record

Summary

When the procedure was first captured in the subject's record

Description

The extension URL is: https://fhir.clevermed.com/StuctureDefinition/Procedure-recordedDateTime

Mandatory

Yes

Expected type

🌍dateTime

Write allowed

Yes

Data Dictionary item

None

* performedDateTime - When the procedure was performed

Summary

When the procedure was performed

Mandatory

Yes

Expected type

🌍dateTime

Write allowed

Yes

Data Dictionary item

None

* category - Classification of the procedure

Summary

Classification of the procedure

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: '268445003', CodeSystem: 'snomed'', Display: 'Ultrasound scan - obstetric'

* code - Identification of the procedure

Summary

Identification of the procedure

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

UltrasoundScans - Ultrasound scans
   - DataSet: (NZHISOMAT4) New Zealand HISO Maternity data set (Phase 4)
   - Topic: (CurrPregnancy) Current pregnancy details

Value set used

🌍ValueSet-BNet-Preg-UltrasoundScan

* annotation.text - Ultrasound scan order

Summary

Ultrasound scan order

Description

Order number of ultrasound scans during the current pregnancy, representing the total number of ultrasound scans up until this scan.

Mandatory

Yes

Expected type

🌍markdown

Write allowed

No

Data Dictionary item

UltrasoundScans_Total - Ultrasound scan total
   - DataSet: (NZHISOMAT4) New Zealand HISO Maternity data set (Phase 4)
   - Topic: (CurrPregnancy) Current pregnancy details

valueCodeableConcept.text - String for when the code selected is 241491007

Summary

String for when the code selected is 241491007

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.