Skip to main content
Skip table of contents

Procedure-BNet-Labour-Augmentation

FHIR Resource information

FHIR Resource

🌍Procedure-BNet-Labour-Augmentation. Based on 🌍 Procedure

Description

Augmentation of the first or second stage of labour.

Release status

LIVE

Cardinality

single

Writing to Spine permitted

YES - for Spine Client Type (MAT)

Spine filters

None

Key FHIR Resource elements used

id - Unique resource identifier

Summary

Unique resource identifier

Mandatory

No

Expected type

🌍string

Write allowed

No

Data Dictionary item

None

* subject - Reference to the mother/pregnant person

Summary

Reference to the mother/pregnant person

Mandatory

Yes

Value type

🌍Reference(Patient)

Write allowed

Yes

Data Dictionary item

None

* status - Status of the procedure

Summary

Status of the procedure

Mandatory

Yes

Expected type

🌍code

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value of 'completed' should be used.

* category - Category of procedure

Summary

Category of procedure

Description

Fixed code that determines that this procedure is for labour augmentation. An additional value set code to determine whether the procedure is related to the first or second stage of labour

Mandatory

Yes

Expected type

🌍CodeableConcept

Write allowed

Yes

Data Dictionary item

None

Value set used

🌍ValueSet-BNet-Preg-LabStage

* code - Types of labour augmentation

Summary

Types of labour augmentation

Mandatory

Yes

Expected type

🌍CodableConcept

Write allowed

Yes

Data Dictionary items

Lab1st_LabAug - Labour 1st Stage - Labour augmented
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth
Lab2nd_LabAug - Labour 2nd Stage - Labour augmentation
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth

Value set used

🌍ValueSet-BNet-Preg-LabAugment

reasonCode - Reason for augmentation

Summary

Reason for augmentation

Mandatory

No

Expected type

🌍CodableConcept

Write allowed

Yes

Data Dictionary items

Lab1st_AugReason - Labour 1st Stage - Reason labour augmented
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth
Lab2nd_AugReason - Labour 2nd Stage - Reason labour augmented
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth

Value set used

🌍ValueSet-BNet-Preg-LabAugmentReason

reasonCode.text - If the reason for augmentation is other, the text for other is stored here

Summary

If the reason for augmentation is other, the text for other is stored here

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary items

Lab1st_AugReasonOther - Labour 1st Stage - Reason labour augmented ‘Other’ – detail
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth
Lab2nd_AugReasonOther - Labour 2nd Stage - Reason labour augmented – ‘Other’ detail
   - DataSet: (NZHISOMAT2) New Zealand HISO Maternity data set (Phase 2)
   - Topic: (LabourBirth) Labour and birth

encounter - Reference to the labour and birth encounter

Summary

Reference to the labour and birth encounter

Mandatory

No

Value type

🌍Reference(Encounter)

Write allowed

Yes

Data Dictionary item

None

Example JSON when WRITING to the Spine

JSON
{
  "resourceType": "Procedure",
  "status": "completed",
  "category": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "6893006",
        "display": "First Stage Of Labour"
      }
    ]
  },
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "816966004",
        "display": "Augmented with oxytocin"
      }
    ]
  },
  "subject": {
    "reference": "Patient/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
    "type": "Patient"
  },
  "reasonCode": [
    {
      "coding": [
        {
          "system": "https://fhir.clevermed.com/valuset/LabAugmentReason",
          "code": "1",
          "display": "Delay in first or second stage of labour"
        }
      ]
    }
  ]
}

Example JSON when READING from the Spine

JSON
{
  "resourceType": "Procedure",
  "id": "4F62736572766174696F6E2D424E65742D4368696C642D436F6E67656E6974616C4D616C666F726D6174696F6E73",
  "meta": {
    "profile": [
      "https://fhir.clevermed.com/StructureDefinition/Procedure-BNet-Labour-Augmentation"
    ]
  },
  "status": "completed",
  "category": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "6893006",
        "display": "First Stage Of Labour"
      }
    ]
  },
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "816966004",
        "display": "Augmented with oxytocin"
      }
    ]
  },
  "subject": {
    "reference": "Patient/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
    "type": "Patient"
  },
  "reasonCode": [
    {
      "coding": [
        {
          "system": "https://fhir.clevermed.com/valuset/LabAugmentReason",
          "code": "1",
          "display": "Delay in first or second stage of labour"
        }
      ]
    }
  ]
}


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.