Skip to main content
Skip table of contents

Observation-BloodPressure

FHIR Resource information

FHIR Resource

🌍Observation-BloodPressure. Based on 🌍 Observation

Description

Blood Pressure

Release status

LIVE

Cardinality

Multiple Instance (date/time)

Writing to Spine permitted

YES - for Spine Client Type (MAT)

Should be sent to Spine if available.

Spine filters

PREGSUM

FHIR Observation resource details

Observation details

Code

35094-2 (🌍loinc)

Value type

🌍string

Resource Element

valueString

Mandatory

Yes

Uses effectiveDateTime

Yes

Data Dictionary item

MatBP - Blood pressure of woman
   - DataSet: (PREGSUMUK) UK PREGSUM Maternity Data set
   - Topic: (MatBooking) Details at pregnancy booking

Key FHIR Resource elements used

* effectiveDateTime - Clinically relevant time/time-period for observation

Summary

Clinically relevant time/time-period for observation

Mandatory

Yes

Expected type

🌍dateTime

Write allowed

Yes

Data Dictionary item

None

* component.coding.code - Fixed code for systolic blood pressure

Summary

Fixed code for systolic blood pressure

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: '8480-6', CodeSystem: 'loinc'', Display: 'Systolic blood pressure'

* component.valueQuantity.value - Systolic blood pressure for patient in units of mm[Hg]

Summary

Systolic blood pressure for patient in units of mm[Hg]

Description

The decimal value is restricted to [0,300].

Mandatory

Yes

Expected type

🌍decimal

Write allowed

Yes

Data Dictionary item

None

* component.valueQuantity.unit - Unit representation

Summary

Unit representation

Mandatory

Yes

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

* component.valueQuantity.code - System that defines coded unit form

Summary

System that defines coded unit form

Mandatory

Yes

Expected type

🌍code

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value of 'mm[Hg]' should be used.

* component.coding.code - Fixed code for diastolic blood pressure

Summary

Fixed code for diastolic blood pressure

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: '8462-4', CodeSystem: 'loinc'', Display: 'Diastolic blood pressure'

* component.valueQuantity.value - Diastolic blood pressure for patient in units of mm[Hg]

Summary

Diastolic blood pressure for patient in units of mm[Hg]

Description

The decimal value is restriced to [0,200].

Mandatory

Yes

Expected type

🌍decimal

Write allowed

Yes

Data Dictionary item

None

* component.valueQuantity.unit - Unit representation

Summary

Unit representation

Mandatory

Yes

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

* component.valueQuantity.code - System that defines coded unit form

Summary

System that defines coded unit form

Mandatory

Yes

Expected type

🌍code

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value of 'mm[Hg]' should be used.

* status - Fixed code for the status of this observation

Summary

Fixed code for the status of this observation

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'final' should be used.

Example JSON when WRITING to the Spine

JSON
{
  "resourceType": "Observation",
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "35094-2"
      }
    ]
  },
  "valueString": "a str value"
}

Example JSON when READING from the Spine

JSON
{
  "resourceType": "Observation",
  "id": "4F62736572766174696F6E2D426C6F6F645072657373757265",
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/workflow-episodeOfCare",
      "valueReference": {
        "reference": "EpisodeOfCare/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD"
      }
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "35094-2"
      }
    ]
  },
  "valueString": "a str value"
}


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.