Skip to main content
Skip table of contents

CarePlan-BNet-Preg-PostnatalManagementPlan

FHIR Resource information

FHIR Resource

🌍CarePlan-BNet-Preg-PostnatalManagementPlan. Based on 🌍 CarePlan

Description

Postnatal Management Plan

Release status

LIVE

Cardinality

Single Instance

Writing to Spine permitted

NO

Spine filters

PREGSUM

Key FHIR Resource elements used

category - Fixed code for obstetric postnatal care plan.

Summary

Fixed code for obstetric postnatal care plan.

Description

Fixed single SNOMED code that identifies this CAREPLAN resource as being for the obstetric postnatal care plan.

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value: '773432009', CodeSystem: 'snomed'', Display: 'Obstetric postnatal care plan'

created - Date and time when this is to be recorded in patient notes.

Summary

Date and time when this is to be recorded in patient notes.

Mandatory

No

Expected type

🌍dateTime

Write allowed

No

Data Dictionary item

None

* status - Indicates that the plan is in force and ready to be acted upon

Summary

Indicates that the plan is in force and ready to be acted upon

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'active' should be used.

* intent - Indicates the level of authority/intentionality associated with the care plan and where the care plan fits into the workflow chain.

Summary

Indicates the level of authority/intentionality associated with the care plan and where the care plan fits into the workflow chain.

Description

The fixed value here represents an intention which ensures that the careplan can occur without further authorisation for others to act.

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'plan' should be used.

* subject - A reference to the patient that this care plan is for

Summary

A reference to the patient that this care plan is for

Mandatory

Yes

Value type

🌍Reference(Patient)

Write allowed

No

Data Dictionary item

None

* activity.detail.code - Code to define whether this is a revised or actual management plan

Summary

Code to define whether this is a revised or actual management plan

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

No

Data Dictionary item

None

Value set used

🌍ValueSet-BNet-Preg-ManagementPlanRevision

activity.detail.description - Description of the postnatal management plan

Summary

Description of the postnatal management plan

Mandatory

No

Expected type

🌍string

Write allowed

No

Data Dictionary item

PostnatalManagementPlan - PostnatalManagementPlan
   - DataSet: (PREGSUMUK) UK PREGSUM Maternity Data set
   - Topic: (ManagementPlans) Current management plans

Extension.PlanAgreed - Boolean to determine whether woman agrees with the plan

Summary

Boolean to determine whether woman agrees with the plan

Mandatory

No

Expected type

🌍Boolean

Write allowed

No

Data Dictionary item

None

* activity.detail.status - Status of the activity

Summary

Status of the activity

Mandatory

Yes

Expected type

🌍code

Write allowed

No

Data Dictionary item

None

Fixed value

Fixed code value of 'scheduled' should be used.

Example JSON when READING from the Spine

JSON
{
  "resourceType": "CarePlan",
  "id": "3436393734323535396534303466663539326133336138353938393436326162",
  "meta": {
    "profile": [
      "https://fhir.clevermed.com/StructureDefinition/CarePlan-BNet-Preg-PostnatalManagementPlan"
    ]
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/workflow-episodeOfCare",
      "valueReference": {
        "reference": "EpisodeOfCare/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD"
      }
    }
  ],
  "status": "active",
  "intent": "plan",
  "category": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "773432009",
          "display": "Obstetric postnatal care plan"
        }
      ]
    }
  ],
  "subject": {
    "reference": "Patient/pfnmwufwgslhi6anetz6ogttq-h4bvgwlh.mvftzt5kuk5c8qxyc7weacnmtu.md"
  },
  "created": "2025-03-25T15:48:12.9576818+00:00",
  "activity": [
    {
      "detail": {
        "status": "scheduled",
        "description": "This is a management plan"
      }
    }
  ]
}


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.