Skip to main content
Skip table of contents

Observation-BNet-Preg-CTG-DRResult

FHIR Resource information

FHIR Resource

🌍Observation-BNet-Preg-CTG-DRResult. Based on 🌍 Observation

Description

Dawes Redmond Analysis of Cardiotocography Scan

Release status

LIVE

Cardinality

Single Instance

Writing to Spine permitted

YES - for Spine Client Type (MAT)

Spine filters

None

FHIR Observation resource details

Observation details

Value type

🌍UNKNOWN

Mandatory

Yes

Uses effectiveDateTime

Yes

Data Dictionary item

None

Key FHIR Resource elements used

* code - Fixed code for the code of the observation

Summary

Fixed code for the code of the observation

Mandatory

Yes

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: '251666009', CodeSystem: 'snomed'', Display: 'Cardiotochogram finding (finding)'

* status - Fixed code for the status of the observation

Summary

Fixed code for the status of the observation

Mandatory

Yes

Expected type

🌍code

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value of 'final' should be used.

* effectiveDateTime - Date and time, in UTC, to the second of the Dawes Redmond analysis of the trace

Summary

Date and time, in UTC, to the second of the Dawes Redmond analysis of the trace

Mandatory

Yes

Expected type

🌍dateTime

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for 'CTG Met Within' for 1st Fetus

Summary

Fixed code for 'CTG Met Within' for 1st Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRMet_1st', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'CTG Met Within for 1st Fetus'

component.valueInteger - Time for 'CTG Met Within' for Dawes Redmond analysis for 1st Fetus in minutes.

Summary

Time for 'CTG Met Within' for Dawes Redmond analysis for 1st Fetus in minutes.

Description

Only one 'Time for 'CTG Met Within'' can be sent for the 1st fetus.

Mandatory

No

Expected type

🌍integer

Write allowed

Yes

Data Dictionary item

None

component.valueQuantity.unit - Unit for 'CTG Met Within'. This is set to 'minutes'

Summary

Unit for 'CTG Met Within'. This is set to 'minutes'

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for STV for 1st Fetus

Summary

Fixed code for STV for 1st Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRSTV_1st', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'STV Value for 1st Fetus'

component.valueQuantity.value - STV value from Dawes Redmond analysis for 1st Fetus.

Summary

STV value from Dawes Redmond analysis for 1st Fetus.

Description

Only one 'STV value' can be sent for the 1st fetus. Additionally, the maximum number of decimal places that are supported are 5.

Mandatory

No

Expected type

🌍decimal

Write allowed

Yes

Data Dictionary item

None

component.valueQuantity.unit - Unit for STV value. The unit is 'ms' for milliseconds

Summary

Unit for STV value. The unit is 'ms' for milliseconds

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for details of CTG for 1st Fetus

Summary

Fixed code for details of CTG for 1st Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRDetails_1st', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'Details of CTG for 1st Fetus'

component.valueString - Details of Dawes Redmond result for 1st Fetus.

Summary

Details of Dawes Redmond result for 1st Fetus.

Description

Only one details string can be sent for the 1st fetus.

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for when CTG Met Within for 2nd Fetus

Summary

Fixed code for when CTG Met Within for 2nd Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRMet_2nd', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'CTG Met Within for 2nd Fetus'

component.valueInteger - Time for 'CTG Met Within' for Dawes Redmond analysis for 2nd Fetus in minutes

Summary

Time for 'CTG Met Within' for Dawes Redmond analysis for 2nd Fetus in minutes

Mandatory

No

Expected type

🌍integer

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for STV for 2nd Fetus

Summary

Fixed code for STV for 2nd Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRSTV_2nd', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'STV Value for 2nd Fetus'

component.valueQuantity.value - STV value for Dawes Redmond analysis for 2nd Fetus.

Summary

STV value for Dawes Redmond analysis for 2nd Fetus.

Description

Only one 'STV Value' can be sent for the 2nd fetus. Additionally, the maximum number of decimal places that are supported are 5.

Mandatory

No

Expected type

🌍decimal

Write allowed

Yes

Data Dictionary item

None

component.valueQuantity.unit - Unit for STV value. The unit is 'ms' for milliseconds.

Summary

Unit for STV value. The unit is 'ms' for milliseconds.

Description

Only one 'STV value' can be sent for the 2nd fetus.

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

component.code - Fixed code for details of CTG for 2nd Fetus

Summary

Fixed code for details of CTG for 2nd Fetus

Mandatory

No

Expected type

🌍codeableConcept

Write allowed

Yes

Data Dictionary item

None

Fixed value

Fixed code value: 'CTGDRDetails_2nd', CodeSystem: 'https://fhir.clevermed.com/codesystem/BadgerNet'', Display: 'Details of CTG for 2nd Fetus'

component.valueString - Details of Dawes Redmond result for 2nd Fetus.

Summary

Details of Dawes Redmond result for 2nd Fetus.

Description

Only one details string can be sent for the 2nd fetus.

Mandatory

No

Expected type

🌍string

Write allowed

Yes

Data Dictionary item

None

Example JSON when WRITING to the Spine

JSON
{
  "resourceType": "Observation",
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/workflow-episodeOfCare",
      "valueReference": {
        "reference": "pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
        "display": "Patient"
      }
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "251666009"
      }
    ]
  },
  "subject": {
    "reference": "Patient/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
    "type": "Patient"
  },
  "effectiveDateTime": "2025-07-31T15:55:07.9684893+00:00",
  "component": [
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRMet_1st"
          }
        ]
      },
      "valueInteger": 5
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRSTV_1st"
          }
        ]
      },
      "valueQuantity": {
        "value": 5.5,
        "unit": "ms",
        "system": "http://unitsofmeasure.org",
        "code": "ms"
      }
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRDetails_1st"
          }
        ]
      },
      "valueString": "Details of CTG for 1st fetus"
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRMet_2nd"
          }
        ]
      },
      "valueInteger": 4
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRSTV_2nd"
          }
        ]
      },
      "valueQuantity": {
        "value": 8.8,
        "unit": "ms",
        "system": "http://unitsofmeasure.org",
        "code": "ms"
      }
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRDetails_2nd"
          }
        ]
      },
      "valueString": "Details of CTG for 2nd fetus"
    }
  ]
}

Example JSON when READING from the Spine

JSON
{
  "resourceType": "Observation",
  "id": "4F62736572766174696F6E2D424E65742D4368696C642D436F6E67656E6974616C4D616C666F726D6174696F6E73",
  "meta": {
    "profile": [
      "https://fhir.clevermed.com/StructureDefinition/Observation-BNet-Preg-CTG-DRResult"
    ]
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/workflow-episodeOfCare",
      "valueReference": {
        "reference": "pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
        "display": "Patient"
      }
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "251666009"
      }
    ]
  },
  "subject": {
    "reference": "Patient/pfnmWUFWGSLHi6aneTz6oGtTq-h4BVgwlH.mvFTZT5kuK5c8QXyC7WeACnmTu.mD",
    "type": "Patient"
  },
  "effectiveDateTime": "2025-07-31T15:52:07.9690186+00:00",
  "component": [
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRMet_1st"
          }
        ]
      },
      "valueInteger": 5
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRSTV_1st"
          }
        ]
      },
      "valueQuantity": {
        "value": 5.5,
        "unit": "ms",
        "system": "http://unitsofmeasure.org",
        "code": "ms"
      }
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRDetails_1st"
          }
        ]
      },
      "valueString": "Details of CTG for 1st fetus"
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRMet_2nd"
          }
        ]
      },
      "valueInteger": 4
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRSTV_2nd"
          }
        ]
      },
      "valueQuantity": {
        "value": 8.8,
        "unit": "ms",
        "system": "http://unitsofmeasure.org",
        "code": "ms"
      }
    },
    {
      "code": {
        "coding": [
          {
            "system": "https://fhir.clevermed.com/valueset/BNet-Preg-CTG-DRResult",
            "code": "CTGDRDetails_2nd"
          }
        ]
      },
      "valueString": "Details of CTG for 2nd fetus"
    }
  ]
}


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.