Skip to main content
Skip table of contents

Encounter-BNet-Child-NNUDaySummary

FHIR Resource information

FHIR Resource

🌍Encounter-BNet-Child-NNUDaySummary. Based on 🌍 Encounter

Description

Neonatal day summary base

Release status

NOT AVAIL. (RFC)

Cardinality

Multi instance on date

Writing to Spine permitted

YES - for Spine Client Type (NNU-SYSTEM)

Spine filters

NNU-DETAIL

Key FHIR Resource elements used

subject - Reference back to root child patient resource. The root patient resource should have an ID of $“Patient/{LogicalID}”

Summary

Reference back to root child patient resource. The root patient resource should have an ID of $“Patient/{LogicalID}”

Mandatory

No

Value type

🌍Reference(Patient)

Write allowed

Yes

Data Dictionary item

None

period - Refers to the 24 hour time period starting midnight

Summary

Refers to the 24 hour time period starting midnight

Mandatory

No

Expected type

🌍dateTime

Write allowed

Yes

Data Dictionary item

None

serviceProvider - Reference to the BadgerNet care location for the episode linked to this day

Summary

Reference to the BadgerNet care location for the episode linked to this day

Mandatory

No

Expected type

🌍reference

Write allowed

No

Data Dictionary item

None

extension:RespiratorySupport - Highest level of respiratory support for a single calendar day

Summary

Highest level of respiratory support for a single calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

extension:LastWeightInDay - Last measured weight in calendar day

Summary

Last measured weight in calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

extension:ApnoeaToday - Apnoea occurred at any time in calendar day

Summary

Apnoea occurred at any time in calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

extension:BarrierNursed - Barrier Nursed at any time in calendar day

Summary

Barrier Nursed at any time in calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

extension:Phototherapy - Phototherapy given at any time in calendar day

Summary

Phototherapy given at any time in calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

extension:MaxBilirubin - Max Bilirubin in calendar day

Summary

Max Bilirubin in calendar day

Mandatory

No

Expected type

🌍extension

Write allowed

Yes

Data Dictionary item

None

Example JSON when WRITING to the Spine

Example JSON pending, awaiting development.

Example JSON when READING from the Spine

Example JSON pending, awaiting development.


CONFIDENTIAL/COMMERCIAL IN CONFIDENCE

Confidentiality/document control

This document contains information that is confidential to System C Healthcare Ltd (System C) and is intended for our customers to use in connection with our products and services. It must not be used for any other purpose nor disclosed to any other party, either whole or in part, without the prior written consent of System C except as follows. A customer may permit those of its employees, advisors and agents having a need to know the contents of this platform to have access to such of the contents as are strictly necessary, but that customer shall ensure that such employees, advisors and agents are bound to it by an obligation, in similar term, to keep it confidential. A customer's acceptance of these obligations shall be indicated by that customer's use of any of the information contained in this document.

System C acknowledges that a customer may be bound by the Freedom of Information Act 2000 (FOIA). In such cases, System C considers that the contents of this document are confidential and exempt from disclosure pursuant to section 41 of the FOIA. A customer should consult System C before making any disclosure of information relating to System C under the FOIA. System C's business information, methodologies, solutions, as well as reference to System C clients and their projects, are always considered by System C to be exempt from disclosure by virtue of section 41 and 43 of the FOIA, whether indicated or not. 

Product Information: any descriptions of future functionality reflect current product direction, are for informational purposes only, and do not constitute a commitment to provide specific functionality. Timing and availability remain at System C’s discretion and are subject to change and applicable regulatory approvals.

Warning: Paper or PDF copies of this document are not version controlled and will automatically be considered obsolete and superseded at the time of printing or conversion.

Confidentiality/document control statement version number 2.0, QMSUID-0059
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.